OMNIS bietet Leistung in der Titration auf einem ganz neuen Level
OMNIS bietet Leistung in der Titration auf einem ganz neuen Level
OMNIS bietet Leistung in der Titration auf einem ganz neuen Level
OMNIS bietet Leistung in der Titration auf einem ganz neuen Level
OMNIS bietet Leistung in der Titration auf einem ganz neuen Level

THE OMNIS TITRATOR – YOUR GATEWAY TO THE FUTURE OF TITRATION

OMNIS is a modular analysis platform that offers more: more safety, more convenience, more performance. And it saves more time, too – with its optimized titration algorithm that ensures faster results. Find out about the benefits of the OMNIS analysis platform, feature by feature – starting with the OMNIS titrator!

FEATURES

  • The basic module of the OMNIS titration platform
  • Space for two measurement inputs (digital and analog)
  • Can be expanded as needed with up to four additional burettes and eight measurement inputs
  • Modular firmware design – the titration modes for potentiometric or volumetric Karl Fischer titration can be selected based on individual needs. Further modes/functionalities can be retrofitted at any time
  • LEDs indicate that the system is ready for measurement
Faster
Safer
Easier

OMNIS LIQUID ADAPTER WITH 3S TECHNOLOGY

Just snap the OMNIS Liquid Adapter onto the reagent bottle – that’s how easy and fast reagent exchanges are with OMNIS! Because the bottle doesn’t have to be opened, there is no contact with hazardous liquids. OMNIS reads the bottle content data from an RFID chip in the bottle lid, making the analysis traceable back to the reagent.

FEATURES

  • 3S technology: safe, secure, smart
  • Contact-free reagent exchange
  • Patented system that combines safety and simple application
  • Automatic transfer of reagent data to the OMNIS Software
http://www.sigma-aldrich.com/3S
Faster
Safer
Easier

THE OMNIS BURETTE

Dosing with a resolution of 100,000 steps! That means maximum precision when adding reagents and auxiliary solutions, which is reflected in the quality of your measurement results.

FEATURES

  • 5, 10, 20 and 50 mL cylinder volumes
  • Burette resolution of 100,000 steps
Faster
Safer
Easier

The OMNIS SOLVENT MODULE

Karl Fischer titration with OMNIS means that the titration cell is filled and conditioned automatically using the OMNIS solvent module. The titration itself starts automatically after you have introduced the sample. The titrated sample is disposed of and the cell is prepared for the next titration – automatically. All you need to do is start the process with a single mouse-click.

FEATURES

  • Automatic filling and emptying of the titration cell with solvent
  • Titration starts automatically once the sample has been introduced
  • Sample weight is automatically transferred from the balance into the method
Faster
Safer
Easier

TWO MEASUREMENT INPUTS

Your OMNIS Titrator provides space for 2 measurement inputs. You can measure with both digital and analog sensors, depending on the measurement input. The measurement input (digital or analog) is easily inserted into the provided shaft on the titrator. This allows measurement inputs to be effortlessly replaced or retrofitted.

FEATURES

  • Space for 2 measurement inputs per titrator/titration module
  • Measurement inputs (digital or analog) can be retrofitted or replaced at any time
  • Use analog or digital sensors
  • Signal transmission via an optical interface
  • Complete measurement traceability
Faster
Safer
Easier

dTRODES – UNIQUE ELECTRODES

The new generation of Metrohm electrodes is impressive due to their compact, space-saving design. Digitalization of the analog measurement signal is integrated into the electrode head, so signal transmission is not affected by electrostatic influences. A data chip in the sensor head allows the calibration date and validity to be monitored, so the measurement is traceable: Upon connection to the titrator, all sensor data is captured and stored in the sensor list.

FEATURES

  • Measurement amplifier and signal conversion integrated into one robust sensor
  • Bayonet closure makes it easy to connect the electrode
  • Automatic sensor detection
  • Data chip allows extensive monitoring of sensor data and measurement traceability
Faster
Safer
Easier

RETROFIT BURETTES AND MEASUREMENT INPUTS

Need more capacity? Expand your OMNIS Basic Titrator with additional burettes and measurement inputs. Add a dosing module for one extra burette. With an additional titration module, you provide up to 2 more measurement inputs in addition to another burette. In total, your OMNIS Basic Titrator can be expanded by up to 4 burettes and 8 measurement inputs!

FEATURES

  • The OMNIS Dosing Module provides an additional burette
  • The OMNIS Titration Module provides 2 additional measurement inputs
  • Dosing or titration modules can be retrofitted at any time
Faster
Safer
Easier

THE OMNIS SAMPLE ROBOT

High cost pressure? Retrofit your OMNIS titrator for manual operation with an OMNIS Sample Robot and OMNIS can process your samples automatically. Modular scalability in capacity: from the OMNIS Sample Robot S (up to 50 samples) to the model M (up to 125 samples) and on to the OMNIS Sample Robot L, which offers space for up to 175 samples on seven racks – you’ll have enough capacity to analyze even very large sample series automatically.

FEATURES

  • Modular scalability from expansion stage S (two racks, max. 50 samples) to M (five racks, max. 125 samples) to L (seven racks)
  • Sample Robot L offers space for up to seven racks for up to 175 samples
  • Can be used with beaker sizes of 75, 120, 200 and 250 ml
  • Various beaker materials (glass, brown glass and polypropylene) allow the OMNIS Sample Robot to be used for wide range of applications
  • Racks with samples that have already been analyzed can be replaced as operation continues
Faster
Safer
Easier

SIMULTANEOUS TITRATION AT FOUR WORKSTATIONS

Looking for maximum sample throughput? Your OMNIS sample robot offers space for up to four workstations where up to four measurements can be carried out simultaneously – with full automation. Performing four measurements simultaneously results in time savings of 60% when compared with the sequential measurement of the same samples at one workstation. After the samples have been processed using your OMNIS Sample Robot, they can be replaced by new samples at any time – even as operation continues.

FEATURES

  • Simultaneous titration at up to four workstations
  • The OMNIS DisCover sample containers on the OMNIS Sample Robot can be closed and opened again automatically – airtight and dustproof
  • Retrofit workstations as necessary
  • Space for up to eight pumps to handle liquids easily
Faster
Safer
Easier

Our titration specialists are there for you