1
2
3
4
5
6
7
8
OMNIS bietet Leistung in der Titration auf einem ganz neuen Level
OMNIS bietet Leistung in der Titration auf einem ganz neuen Level
OMNIS bietet Leistung in der Titration auf einem ganz neuen Level
OMNIS bietet Leistung in der Titration auf einem ganz neuen Level
OMNIS bietet Leistung in der Titration auf einem ganz neuen Level

THE OMNIS BASIC TITRATOR – YOUR GATEWAY TO THE FUTURE OF TITRATION

OMNIS is the modular analysis platform that offers more: more safety, more convenience, more performance. But also more time saved – such as through the optimized titration algorithm that ensures that the results are available faster. Learn about the benefits of the OMNIS analysis platform, feature by feature – starting with the OMNIS Basic Titrator!

FEATURES

  • The basic module of the OMNIS titration platform
  • Space for 2 measurement inputs (digital and analog)
  • Can be expanded as required by up to 4 additional burettes and 8 measurement inputs
  • Modular firmware design – titration and measurement modes can be expanded at any time
  • LEDs indicate measurement readiness
Faster
Safer
Easier

OMNIS LIQUID ADAPTER WITH 3S TECHNOLOGY

Just snap the OMNIS Liquid Adapter onto the reagent bottle – that’s how easy and fast reagent exchanges are with OMNIS! Because the bottle doesn’t have to be opened, there is no contact with hazardous liquids. OMNIS reads the bottle content data from an RFID chip in the bottle lid, making the analysis traceable back to the reagent.

FEATURES

  • 3S technology: safe, secure, smart
  • Contact-free reagent exchange
  • Patented system that combines safety and simple application
  • Automatic transfer of reagent data to the OMNIS Software
Faster
Safer
Easier

THE OMNIS BURETTE

Dosing with a resolution of 100,000 steps! That means maximum precision when adding reagents and auxiliary solutions, which is reflected in the quality of your measurement results.

FEATURES

  • 5, 10, 20 and 50 mL cylinder volumes
  • Burette resolution of 100,000 steps
Faster
Safer
Easier

TWO MEASUREMENT INPUTS

Your OMNIS Titrator provides space for 2 measurement inputs. You can measure with both digital and analog sensors, depending on the measurement input. The measurement input (digital or analog) is easily inserted into the provided shaft on the titrator. This allows measurement inputs to be effortlessly replaced or retrofitted.

FEATURES

  • Space for 2 measurement inputs per titrator/titration module
  • Measurement inputs (digital or analog) can be retrofitted or replaced at any time
  • Use analog or digital sensors
  • Signal transmission via an optical interface
  • Complete measurement traceability
Faster
Safer
Easier

dTRODES – UNIQUE ELECTRODES

The new generation of Metrohm electrodes is characterized by their compact, space-saving design. Digitalization of the analog measurement signal is integrated into the electrode head, making the signal transmission insensitive to electrostatic influences. A data chip in the head of the sensor enables monitoring of calibration data and validity, making the measurement traceable: upon connection to the titrator, all sensor data is captured and stored in the sensor list.

FEATURES

  • Measurement amplifier and signal conversion integrated into one robust sensor
  • Bayonet closure for simple connection of the electrode
  • Automatic detection of the sensor
  • Data chip enables extensive monitoring of sensor data and traceability of the measurement
Faster
Safer
Easier

RETROFIT BURETTES AND MEASUREMENT INPUTS

Need more capacity? Expand your OMNIS Basic Titrator with additional burettes and measurement inputs. Add a dosing module for one extra burette. With an additional titration module, you provide up to 2 more measurement inputs in addition to another burette. In total, your OMNIS Basic Titrator can be expanded by up to 4 burettes and 8 measurement inputs!

FEATURES

  • The OMNIS Dosing Module provides an additional burette
  • The OMNIS Titration Module provides 2 additional measurement inputs
  • Dosing or titration modules can be retrofitted at any time
Faster
Safer
Easier

THE OMNIS SAMPLE ROBOT

Upgrade when the time is right! Set up your OMNIS Basic Titrator for manual operation with an OMNIS Sample Robot and OMNIS will process your samples automatically. The capacity can be scaled to your needs: from the OMNIS Sample Robot S (up to 50 samples) to the model M (up to 125 samples) to the OMNIS Sample Robot L, which provides space for up to 175 samples on 7 racks – enough capacity to automate analyses of very large sample series.

FEATURES

  • Modular scalability from expansion stage S (2 racks, max. 50 samples) to M (5 racks, max. 125 samples) to L (7 racks)
  • Place up to 7 racks for up to 175 samples on the Sample Robot L.
  • 75, 120 and 250 mL container sizes can be used
  • Racks with already analyzed samples can be exchanged during ongoing operation
Faster
Safer
Easier

SIMULTANEOUS TITRATION AT 4 WORKSTATIONS

Want maximum sample throughput? Your OMNIS Sample Robot provides space for up to 4 workstations at which you can carry out up to 4 measurements simultaneously – fully automated. The simultaneous performance of 4 measurements means time savings of 60% in comparison to the sequential measurement of the same samples at 1 workstation. Once the samples have been processed on your OMNIS Sample Robot, they can be exchanged for new samples at any time – even during ongoing operation.

FEATURES

  • Titrate simultaneously at up to 4 workstations
  • Upgrade workstations as required
  • Space for up to 8 pumps for simple handling of liquids
Faster
Safer
Easier

Our titration specialists are there for you

Address *

*Required fields

There was an error in the form. Please try again.

Your mail has been sent. Thank you for your request

 
TOP